Alpha Continuity 1000 On-Line UPS, 1000VA/800W | GDFUPS

Your shopping cart is empty.

Alpha Continuity 1000 On-Line UPS, 1000VA/800W

$880.99 CAD

Alpha Continuity 1000 On-Line UPS, 1000VA/800W, 36VDC Battery Bus, 3pcs x 7Ah/12V battery

> Feature rich on-line UPS series with rack / tower convertible design and rotating LCD panel enabling easy integration
into a wide variety of applications and locations
> Wide input power frequency and voltage window accommodates broad operating range for different working requirements
> Advanced digital control technology achieves higher reliability and greater immunity from utility power problems
> Emergency shutdown control through EPO complies with national safety regulations and local code
> Programmable receptacles enable flexible power backup
> Powerful built-in charger shortens battery charging time and extends runtime
> Hot swappable battery allows replacement without interruption to critical loads

Technical Specifications

Electrical

Models

Alpha Continuity 1000

Input

Voltage Window

60~144Vac for 120V system

Frequency

50/60+/-5% (Auto Sensing)

Phase/Wire

Single, Line, + Neutral + Ground

Power Factor

>0.99 (Full Load)

Output

Voltage

100/110/115/120/127Vac

Voltage Regulation

<±0.1% until low battery warning

Capacity

1000VA/800W

Power Factor

0.8* Lagging

Wave Form

Sine Wave, THD<3% (no load to full load)

Frequency Stability

±0.1% unless synchronized to line

Frequency Regulation

3Hz or 1Hz (Setting by software)

Transfer Time

0 m sec

Crest Factor

3:01

Efficiency (AC to AC)

>85%

Autonomy (Built-in Battery)

7.9 mins

DC Start

Yes

Battery

Type

Sealed Lead Acid Maintenance Free

Capacity

7Ah

Quantity

3

Voltage

36Vdc

Recharge Time

3 hours to 90%

Built-in Charger

1.8A

(max. Charging Current)

Models

Continuity 1000

Display

LED

Normal, Battery, Bypass, Programmable Outlet 1, Programmable Outlet 2, Self-Test, Battery Weak & Bad, Site Wiring Fault , Fault, Overload, and Load/Battery Level conditions.

Key

On button / Off button (Test / Alarm silence button)

Self-Diagnostics

Upon Power On and Software Control

Communication Slots

Relay contact board or SNMP card

Protection

Overload AC Mode & Backup Mode (delay before switching to bypass)

<105% continuously.

>106%~120% for 30 seconds transfer to bypass

>121%~150% for 10 seconds transfer to bypass

>150% immediately transfer to bypass

Buzzer continuously alarms

Bypass Mode

<105% continuously.

>106%~120% for 250 seconds shut down

>121%~130% for 125 seconds shut down

>131%~135% for 50 seconds shut down

>136%~145% for 20 seconds shut down

>146%~148% for 5 seconds shut down

>149%~157% for 2 seconds shut down

>158%~176% for 1 seconds shut down

>177%~187% for 0.32 seconds shut down

>188% for 0.16 seconds shut down

Buzzer continuously alarms

Short Circuit

Hold Whole System

Overheat

AC Mode: Switch to Bypass; Backup Mode: UPS shuts down immediately

Battery Low

Alarm and Switch Off

EPO

UPS shuts down immediately

Battery

Advanced Battery Discharge Management (ABDM)

Noise Suppression

115V System

400 Joules

230V System

300 Joules

Alarms

Audible and Visual

Line Failure, Battery Low, Overload, System Fault Conditions

Computer Interface

Interface Type Standard

RS232 and USB Interfaces

Communication Slots

Relay Contact board or SNMP card

 

    Customize your order