Alpha Continuity 6K On-Line UPS, 6kVA/5.4kW | GDFUPS

Your shopping cart is empty.

Alpha Continuity 6K On-Line UPS, 6kVA/5.4kW

$4,180.99 CAD

Alpha Continuity 6K On-Line UPS, 6kVA/5.4kW, 240VDC Battery Bus

Technical Specifications

Electrical

Models

Alpha Continuity 6K

Alpha Continuity 10K

Input

Voltage Window

160~280Vac

Frequency

45-65Hz

Phase/Wire

Single, Line + Ground

Power Factor

Up to 0.99 at 100% Linear Load

Current THD (100% linear load)

<7%

Output

Voltage Window

200/208/220/240Vac Selectable (208/120Vac optional)

Voltage Adjustment

Nominal +1%, +2%, +3%, -1%, -2% or -3%

Voltage Regulation

±1%

±2%

Capacity

6000VA/5400W

10000VA/9000W

Rated Power Factor

0.9 Lagging

0.9 Lagging

Wave Form

Sine Wave, THD<3% (no load to full load)

Frequency Stability

±0.2% (Free Running)

Frequency Regulation

±1Hz; ±3Hz

Transfer Time

0ms

Crest Factor

3:01

Efficiency (AC to AC, Normal)

Up to 90%

Efficiency (AC to AC, ECO)

Up to 95%

Autonomy

7.1 mins

4.8 mins

DC Start

Yes

Battery

Type

Sealed Lead Acid Maintenance Free

Capacity

12V/7Ah

12V/9Ah

Quantity

20pcs

Voltage

240Vdc

Recharge Time

4 hours to 90%

5 hours to 90%

Display

Status On LED + LCD

Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with interruption & UPS Fault.

Readings on LCD

Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature

Self-Diagnostics

Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking

Alarms

Audible and Visual

Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions

Protection

Overload

Inverter Supply:

(w/simulated thermal tripping I-T Curve)

105%~150% for 160 seconds ~ 2 cycles before switching bypass.

 

Bypass Supply:

 

105%~200% for 500 seconds ~8 cycles before stopping supply load.

Short Circuit

Switch off Immediately

Overheat

AC Mode: Switch to Bypass

Backup Mode: Switch off the UPS

Battery Low

Alarm and Switch Off

Noise Suppression

Complies with EN62040-2

Spike suppression

Complies with EN61000-4-5

Heat Dissipation (at full linear load)***

Without Isolated Transformer Module

<450W

10K: <600W

10KP: <550W

With Isolated Transformer Module

<615W

10K: <1100W

10KP: <1050W

Leakage Current

<3ma at="" full="" load="" p="">

Computer Interface

Interface Type

Standard RS232 Interface

Communication Slots

2nd RS232, USB, RS485, Relay Contact or SNMP Card

Customize your order